System Error Code: 16.01:00 – Curing System unable to warm up in the pre-defined amount of time.

System Error Code: 16.01:00 – Curing System unable to warm up in the pre-defined amount of time.

Problem description: Ambient temperature below 15oC. Low AC Voltage. Fans (Curing, Air Curtain, PZ). Curing Resistors. Curing Temperature Sensor. Curing Pressure Sensor.

Corrective action:

1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer’s operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer’s location.

2. Check if the input voltage is outside the range of specifications for printing, see the Site Preparation Guide.

3. Run Service “Curing system monitor”.

4. Check all Fans (Curing, Air Curtain, PZ), all spinning and no obstruction. 94 Chapter 3 System error codes ENWW

5. Reseat/Replace Curing Resistors.

6. Reseat/Replace Curing Temperature Sensors.

7. Reseat/Replace Curing Pressure Sensor.

If this doesn’t solve the problem call or email one of our service engineers: