SE Code: 16.07:03 – Curing system: warm up timeout (uniformity)

SE Code: 16.07:03 – Curing system: warm up timeout (uniformity).

Problem description: Ambient temperature below 15C, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.

Corrective action:

1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer’s operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer’s location.

2. Check the input voltage is outside the range of specifications for printing, see the Site Preparation Guide.

3. Run Service “Curing system monitor.

4. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.

5. Reseat/Replace Curing Resistors.

6. Reseat/Replace Curing Temperature Sensors.

7. Reseat/Replace Curing Pressure Sensor.

If this doesn’t solve the problem call or email one of our service engineers: