SE Code: 16.03:00 – Curing system: high temperature error.

SE Code: 16.03:00 – Curing system: high temperature error.

Problem description: Ambient temperature above 30C, Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.

Corrective action:

1. The environmental ambient temperature is too hot or is outside the operational specification of the printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters etc.

2. Run Service “Curing system monitor”.

3. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.

4. Reseat/Replace Curing Resistors.

5. Reseat/Replace Curing Temperature Sensors.

6. Reseat/Replace Curing Pressure Sensor.

If this doesn’t solve the problem call or email one of our service engineers: